Herunterladen Diese Seite drucken

SATA AE1031H Bedienungsanleitung Seite 153

3d-allrad-locator

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 193
is shown on the display.
8A. Press the
button to start the cycle.
The tyre is inflated to a pressure 60% higher than the set value (within maximum pressure limits). Once the overinflate
pressure is reached, the system deflates the tyre to reach the set value. The pressure is not displayed until the entire
inflation and deflation cycle is com.plete, and three horizontal red bars are shown instead of the value together with a
flashing triangle (Fig. 46c).
Once the cycle is complete, the pressure is displayed again in green and the flashing green triangle disappears (Fig. 46d).
At this stage, inflation has ended.
9A. Disconnect the Doyfe inflation fitting from the wheel.
10A. Fit the inner core of the valve (Fig. 46a).
Note: Press the "STOP" button
cycle at any time.
-The error message A08 ERR_STP is shown on the display (see Fig. 46e).
-Press the
button to exit the INFLATRON function and e return to the
main screen.
6.1.a ERROR MESSAGES
In the event of anomalies, error messages will appear on the display, and all valves will be closed.
A01
Loss of calibration coefficients.
-If the problem persists, contact the technical assistance.
A06
Tubeless procedure or overinflation selected.
-Carry out deflation, when necessary.
A08
Operation stopped with the stop key.
A10
The pressure has not increased after several attempts.
Hose not connected
AE1031H
to stop the automatic inflation
中文
EN
DE
RU
KO
PT
JA
ES
153