4. Select 32" (selection is highlighted with a green border.
5 .Position the demounting tool as shown in fig. 42c and use a feeler
gauge to measure the distance between the tool and the template,
which
6. Press
.The number 32 turns GREEN if the position is
correct. If not, the number turns RED and the message "Calibration
failed" is displayed.
7. Lift the demounting tool.
8. Select 17" (selection is highlighted with a green 9 border).
9.Position the demounting tool as shown in fig.37d and use a feeler
gauge to measure the distance between the tool and the template,
which
10. Press
. If the position is correct, the number 17 turns
GREEN and the message shown in Fig. 42e is displayed.
9.Lift the demounting tool.
10.Switch the machine off, then on again.
NEVER press x-axis calibration during the work phases but only during the calibra¬tion phase with the template
mounted!
5.8.m. P3K DIAGNOSTICS
1.Select P3K DIAGNOSTICS then press the confirm button
43).
2.At the end, Fig. 43a will be displayed.
AE1031H