  • DEUTSCH, seite 193
For the machine to function correctly, the compressed air delivered suitably must be suitably treated (not above 5/4/4
in accordance with ISO 8573-1).
1.2.d TECHNICAL DATA
.Tire types processed..........CONVENTIONAL.LOW PROFILE.RUN FLAT.BALOON BSR
.Wheel dimension range:
•rim diameter..........................................................................from 13" to 32"
•maximum tyre diameter....................................................1200 mm
•maximum tyre width ..........................................................400 mm (16")
.Turntable:
•automatic positioning in relation to.............................. tools
•resting side.............................................................................flanged
•centring....................................................................................on cone
•automatic................................................................................clamping
•drive system...........................................................................2-speed motor-inverter unit
•torque........................................................................................1200 Nm
•rotation speed........................................................................7-20 rpm
.Wheel lifter:
•lifting capacity.......................................................................85 Kg
.Power supply:
•1 Ph mains power..................................................................230V-50/60Hz
•1 Ph mains power (alternative)........................................110V-50/60Hz
•hydraulic unit motor............................................................0.6-0.8 kW
•hydraulic operating pressure...........................................120 bar
•pneumatic operating pressure:.......................................8.10 bar
•min. rated air delivery rate:...............................................160 Nl/min
•Weighted sound pressure level A (L) inpA the work place .........................< 70 dB(A)
The noise levels indicated correspond to emission levels and do not necessarily represent safe operating levels. Although
there is a relationship between emission levels and expo.sure levels,
this cannot be used reliably to establish whether or not further precautions are necessary. The noise levels to which the
operator is exposed to depends on a number of factors, such as duration of exposure, characteristics of the workplace,
other sources of noise etc. Permissible noise exposure limits may also vary from country to country. How.ever, this
information will enable machine users to make a more accurate assessment of hazard and risks.