Yellow at limit of permissible temperature range. It is not advisable to carry out operations according to the WDK
procedure. Temperature range 15.19 °C and 26.30 °C
Red tyre temperature not within permissible range. It is not possible to carry out operations according to the WDK
procedure. Temperature < 15°C or > 30°C. Bring the temperature of the tyre within the permissible range
.Press the
button (see Fig. 49c) to exit the TEMPERATURE SENSOR function and return to the main screen.
TROUBLESHOOTIN
The sensor does not read correctly
Sensor connector disconnected or not connected properly
-Connect the connector correctly (see Fig. 49d). Sensor or read
circuit failure
-If the problem persists, contact the technical

6.5 TPMS

From the main screen (Fig. 50), press the
The TPMS is an electronic device to read pressure sensors and
check their operation, directly on the tyre changer. Specifically,
the operator can:
.Check sensor integrity and operation before car¬rying out any
operation on tyres
-Check that the sensors conveys the correct pressure and temperature values
-Check sensor battery status
-Acquire information on mounting and the torque values of the valves
-Acquire the spare part codes of valves
-Check integrity and operation after carrying operations on tyres
Intended operating conditions
The TMPS has been designed exclusively to diagnose the correct operation of pressure sensor valves, as described in this
manual. Any other use is inappropriate.
Technical data
-Power supply12Vdc
AE1031H