CAD/CAM integration: Data transfer folder label.
Setting up exocad ChairsideCAD
1. In Windows
Explorer, open the exocad Chair-
®
sideCAD folder.
2. Change into the config folder.
3. Open the following file with a text editor:
settings-chairside.xml
4. Inside the file, find the following expression
("tag"):
<NestingInterop2TemporaryFolder>
Directly behind the expression, you will find the
exocad output path.
5. Replace the output path with the letter of the net-
work drive that you recorded followed by a colon
(:).
Example: You recorded the drive letter Z. The
expression in the XML file must be (without line
breaks):
<NestingInterop2TemporaryFolder>
Z:
</NestingInterop2TemporaryFolder>
6. Save and close the XML file.