Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
eng
● The power tool develops very high pressures, in applications with compressed
air of up to 1 MPa/10 bar/145 psi and in pressure tests with water of up to
1.8 MPa/18 bar/261 psi. So be very careful. Never let the power tool operate
unattended. Keep third parties away from the work area when working with the
electrical device.
● Do not use the power tool if it is damaged. There is a danger of accident.
● The power tool is not intended/suitable for permanent connection to the
installation. Disconnect all hoses from the installation after completing the
work. Electrical devices can cause hazards which lead to material damage or
injury when left unattended.
● Never operate the REMS Multi-Push unattended on the drinking water supply
(mains). This could cause water damage.
● Examine the high-pressure hoses for damage every time before using.
Damaged high-pressure hoses can burst and cause injury.
● Only use original high-pressure hoses, fi ttings and couplings for the power
tool. This ensures that the safety of the device is maintained.
● Apply the power tool horizontally and dry for operation. Penetration of water
into the electrical device increases the risk of electric shock.
● Do not aim liquid jet at the power tool, not even for cleaning. Penetration of
water into the electrical device increases the risk of electric shock.
● Do not suck up infl ammable or explosive liquids, for example petrol, oil,
alcohol, solvent, with the power tool. The fumes or liquids can ignite or explode.
● Do not operate the power tool in rooms where there is a risk of explosion.
The fumes or liquids can ignite or explode.
● Protect the power tool against frost. The device could be damaged. Let the
power tool run empty for about 1 minute, if necessary, to drain off remaining water.
● Never let the power tool operate unattended. Switch the power tool off at
the On/Off switch (4) and pull out the mains plug and remove the hoses
from the pipe network and from the installation for longer work breaks.
Electrical devices can cause hazards which lead to material damage or injury
when left unattended.
● Do not operate the power tool on a closed pipe system for a prolonged
period of time. The power tool could be damaged by overheating.
● REMS Multi-Push S may only be operated with software as of "Update 03.40,
Date 2020-04-08". Installation of an older software version on REMS Multi-Push
S is not permitted and will lead to malfunctions. This could damage the power
tool/installation.
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the power tool
safely may not use this power tool without supervision or instruction by a
responsible person. Otherwise there is a risk of operating errors and injuries.
● Only allow trained persons to use the power tool. Apprentices may only use
the power tool when they are over 16, when this is necessary for their training
and when they are supervised by a trained operative.
● Check the power cable of the electric al device and extension leads regularly
for damage. Have these renewed by qualifi ed experts or an authorised REMS
customer service workshop in case of damage.
● Only use approved and appropriate marked extension leads with a suffi cient
cable cross-section. Use extension leads up to a length of 10 m with cable
cross-section 1.5 mm², from 10 – 30 m with cable cross-section 2.5 mm².
Explanation of symbols
WARNING
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Use eye protection
Use hand protection
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark

1 Technical data

Use for the intended purpose
WARNING
WARNING
Only use the power tool for the purpose intended. Failure to do so can result in death
or severe injury.
REMS Multi-Push is intended for
● Flushing of drinking water installations with water in accordance with EN
806-4:2010, according to Technical Rule – Worksheet DVGW W 557 (A) October
2012 "Cleaning and disinfection of drinking water installations" of the DVGW
German Gas and Water Association and according to information leafl et "Flushing,
disinfection and commissioning of drinking water installations" (August 2014)
20
Central Association for Sanitary, Heating, Air Conditioning (ZVSHK), Germany
and for fl ushing radiators and surface heating systems.
● Flushing of drinking waterinstallations with water/air mixture with intermit-
tent compressed air in accordance with EN 806-4:2010, according to Technical
Rule – Worksheet DVGW W 557 (A) October 2012 "Cleaning and disinfection of
drinking water installations" of the DVGW German Gas and Water Association
and according to information leafl et "Flushing, disinfection and commissioning
of drinking water installations" (August 2014) Central Association for Sanitary,
Heating, Air Conditioning (ZVSHK), Germany and for fl ushing radiators and
surface heating systems.
● Flushing pipe systems with a water/air mixture with constant compressed air.
● Flushing/desilting of radiators and area heating systems with/without
compressed air.
● Disinfection with disinfection unit REMS V-Jet TW: Disinfection of drinking
water installations in accordance with EN 806-4:2010, according to Technical
Rule – Worksheet DVGW W 557 (A) October 2012 "Cleaning and disinfection of
drinking water installations" of the DVGW German Gas and Water Association
and according to information leafl et "Flushing, disinfection and commissioning
of drinking water installations" (August 2014) of the Central Association for
Sanitary, Heating, Air Conditioning (ZVSHK), Germany and other pipe systems.
Use of active ingredient REMS Peroxi Color.
● Cleaning and preservation with cleaning and preservation unit REMS V-Jet
H: Cleaning and preservation of radiators and area heating systems. Use of the
active ingredients REMS CleanH and REMS NoCor.
● Leak testing of drinking water installations with compressed air in accord-
Leak testing of drinking water installations with compressed air
Leak testing of drinking water installations with compressed air in accord-
ance with information leafl et "Leak Testing of Drinking Water Installations" (January
2011) of the German Central Association for Sanitary, Heating and Air Conditioning
(ZVSHK) and pressure and leak testing of other pipe systems and vessels (REMS
Multi-Push SL/SLW).
● Load testing of drinking water installations with compressed air in accord-
Load testing of drinking water installations with compressed air in accord-
Load testing of drinking water installations with compressed air
ance with information leafl et "Leak Testing of Drinking Water Installations" (January
2011) of the German Central Association for Sanitary, Heating and Air Conditioning
(ZVSHK) and pressure and load testing of other pipe systems and vessels (REMS
Multi-Push SL/SLW).
● Hydrostatic pressure testing of drinking water installations with water in
accordance with EN 806-4:2010, Test Method A and for pressure and leak testing
of other pipe systems and vessels (REMS Multi-Push SLW).
● Hydrostatic pressure testing of drinking water installations with water in
Hydrostatic pressure testing of drinking water installations with water in
Hydrostatic pressure testing of drinking water installations with water
accordance with EN 806-4:2010, Test Method B, modifi ed in accordance with
information leafl et T 82-2011 "Leak Testing of Drinking Water Installations" of the
German Central Association for Sanitary, Heating and Air Conditioning and pres-
sure and leak testing of other pipe systems and vessels (REMS Multi-Push SLW).
● Hydrostatic pressure testing of drinking water installations with water in
Hydrostatic pressure testing of drinking water installations with water in
Hydrostatic pressure testing of drinking water installations with water
accordance with EN 806-4:2010, Test Method C and for pressure and leak testing
of other pipe systems and vessels (REMS Multi-Push SLW).
● Load testing (strength testing) of gas pipes with compressed air in accord-
ance with EN 1775:2007, according to Technical Rule – Worksheet G 600 April
2008 (DVGW-TRGI 2008) "Technical Rules for Gas Installations" of the DVGW
German Gas and Water Association (REMS Multi-Push SL/SLW).
● Leak testing of gas pipes with compressed air in accordance with EN 1775:2007,
according to Technical Rule – Worksheet G 600 April 2008 (DVGW-TRGI 2008)
"Technical Rules for Gas Installations" of the DVGW German Gas and Water
Association (REMS Multi-Push SL/SLW).
● Compressed air pump for controlled fi lling of all types of vessels with compressed
air ≤ 0.8 MPa/8 bar/116 psi (REMS Multi-Push SL/SLW),
● Operation of compressed air tools up to an air requirements of ≤ 230 Nl/min
All other uses are not for the intended purpose and are therefore prohibited.
Attention: Use for the intended purpose also includes consideration and
Attention: Use for the intended purpose also includes consideration and
observance of the national safety provisions, rules and regulations valid for
observance of the national safety provisions, rules and regulations valid for
the application site, especially the following standards and rules of technology:
the application site, especially the following standards and rules of technology:
Technical Rules for Drinking Water Installations
European standard EN 806-4:2010 "Technical Rules for Drinking Water Instal-
lations – Part 4: Installation"
Based on the currently valid European directive 98/83/EC "on the quality of water
for human consumption", the European standard EN 806-4:2010 "Specifi cations for
installations inside buildings conveying water for human consumption – Part 4:
Installation" was adopted by the European Committee for Standardisation (CEN) on
the 23rd of February 2010 and had to receive the status of a national standard in
all European countries by September 2010. This standard defi nes Europe-wide
regulations for the commissioning of drinking water installations, e.g. for fi lling,
pressure testing, fl ushing and disinfection for the fi rst time.
Section 6 "Commissioning" of EN 806-4:2010 describes the "fi lling and hydrostatic
pressure testing of installations inside buildings for water for human consumption"
under 6.1 "Installations inside buildings must be subjected to pressure testing. This
can be done either with water or, if national regulations allow
if national regulations allow, oil-free, clean air with
low pressure or inert gases may be used. The possible risk from high gas or air
pressure in the system must be considered." However, the standard EN 806-4:2010
contains no test criteria at all for testing with air apart from this note.
Sub-sections to 6.1 offer 3 test methods A, B, C for hydrostatic pressure testing
depending on the material and size of the installed pipes The test methods A, B and
C differ in different test sequences, pressures and times.
eng

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Multi-push slMulti-push slw

Inhaltsverzeichnis