5.2 Fault: Compressor will not start although there is low or no pressure in the compressed air tank (see the display on the compressed air tank pressure gauge
(Fig.4 (30)).
Cause:
● Compressor emergency stop button (Fig.4 (29)) is switched off.
● REMS Multi-Push defective.
5.3 Fault: The necessary minimum fl ow velocity is not achieved in the fl ushing program.
Cause:
● Stop tap of the house connection is only partly open.
● Fine fi lter (Fig. 3 (12)) is contaminated.
● Not enough tapping points opened.
● Hoses connected incorrectly.
● Wrong defaults entered.
● Valves blocked, considerable, irremovable encrustations in the pipes.
5.4 Fault: The set pressure (p refer) is not reached in the test with compressed air or compressed air pump programs (REMS Multi-Push SL/SLW).
Cause:
● Installation or compressed air hose (Fig. 4 (23)) leaking.
● No or too little pressure in the compressed air tank.
● REMS Multi-Push defective.
5.5 Fault: The set pressure (p refer) is not established in the test with water program (Multi-Push SLW).
Cause:
● The water pressure of the house connection is greater than the set pressure
(p refer).
● Suction/pressure hose (Fig. 1 (13)) or high-pressure hose (Fig. 4 (26)) leaking. ● Change suction/pressure hose or high-pressure hose.
● Hydro-pneumatic pump does not build up pressure.
● Stop tap of the water supply is closed or only partly open.
● No or too little air pressure in the compressed air tank.
● REMS Multi-Push defective.
5.6 Fault: The pressure in the pipe to be tested is not relieved after running the test with water programs or during the test with water B, P+M (REMS Multi-Push SLW).
Cause:
● Pressure relief water drain (Fig. 4 (27)) is soiled or defective.
● REMS Multi-Push defective.
5.7 Fault: No or not enough ingredient is injected from the bottle.
Cause:
● Unsuitable disinfectant, cleaning, preserving agent.
● REMS V-Jet TW or REMS V-Jet H connected wrongly to the Multi-Push.
● REMS V-Jet TW or REMS V-Jet H soiled.
● REMS V-Jet TW or REMS V-Jet H defective.
● Wrong REMS V-Jet TW or REMS V-Jet H unit connected.
5.8 Fault: The date and time must be reset every time the REMS Multi-Push is switched on.
Cause:
● Battery depleted.
5.9 Fault: The new version software was not installed.
Cause:
● USB stick not recognised.
● New version software is not on the USB stick.
● The USB stick was pulled out of the USB port
(Fig. 2 (33)) during the installation.
● A folder was created on the USB stick and the new version software was
copied into this folder.
5.10 Fault: The fl ushing and testing programs have been incorrectly displayed on the PC.
Cause:
● The font "Lucida Console" is required for a correct display.
5.11 Fault: Printing on paper weak or illegible. Printout aborted prematurely.
Cause:
● Weak battery charge.
● Paper reel inserted incorrectly in printer.
● The printer can only be used as of Version Software 2.0.
5.12 Fault: "Error" is displayed on the screen (6).
Cause:
● A fault has occurred.
Remedy:
● Switch on compressor by pulling out the emergency stop button.
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Fully open the stop tap.
● Clean or change the fi ne fi lter and fi lter cartridge.
● Open the appropriate number of tapping points.
● Connect hoses as shown in Fig. 3.
● Check defaults, correct if necessary. Restart the program.
● Clean/change valve(s). Clear encrustations.
Remedy:
● Check installation for leaks. Change the compressed air hose.
● See 5.2 Fault:
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Close the shut-off valve of the house connection.
● Connect suction/pressure hose between the house connection and the
pressure test with water supply, see 2.6.2.
● Fully open the stop tap.
● Hydro-pneumatic pump requires compressed air, see 5.2 Fault:
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Clean the pressure relief water drain or have it replaced by qualifi ed personnel
or an authorised REMS customer service workshop.
● Have the REMS Multi-Push checked/repaired by an authorised REMS
customer service workshop.
Remedy:
● Use REMS Peroxi Color, REMS CleanH, REMS NoCor.
● Note the direction of fl ow arrow, see also 2.5.
● Clean REMS V-Jet TW or REMS V-Jet H, see also 4.1.
● Have REMS V-Jet TW or REMS V-Jet H checked/repaired by authorised
REMS customer service workshop.
● Use REMS V-Jet TW exclusively for REMS Peroxi Color.
Use REMS V-Jet H exclusively for REMS CleanH cleaner and REMS NoCor
corrosion protection.
Remedy:
● Change battery. See 4.1.
Remedy:
● Use another USB stick.
● Copy new version software to the USB stick.
● Repeat the procedure described in 2.3.. Use a USB stick with a LED if
possible.
● Move the new version software into the main directory of the USB stick.
Remedy:
● Select font "Lucida Console", install if necessary.
Remedy:
● Charge battery.
● Insert paper roll, see 3.8.
● Load software by USB stick as a download under www.rems.de → Downloads
→ Software into the controller of the REMS Multi-Push, see 2.3.
Remedy:
● Unplug REMS Multi-Push. Remove all hoses, caps and stoppers. Then restart
REMS Multi-Push. If "Error" still appears, have the REMS Multi-Push checked/
repaired by an authorised REMS customer service workshop.