6.3
Connection of compressed air
!
Always connect EPS 118 to a clean, water-free
and oil-free compressed-air supply conforming to
ISO 8573–1:2010 [3:4:4]. In case of poor com-
pressed-air quality, the air filter in the maintenance
unit must be changed sooner. If the air filter is
changed too late, the life cycle of EPS 118 will be
reduced.
The specifications on the compressed air
hose assemblies and distance from the compressed
air supply are described in the chapter "Technical
data" (see sec. 10.1).
!
Compressed air that is too humid may cause mal-
functions and damage. In case of excessive humidity,
an air dryer must be installed in front of the mainte-
nance unit.
i
A transparent bag is attached to the maintenance
unit that has a plug-in hose nipple for a quick lock
connection. Use this plug-in hose nipple for connect-
ing to the compressed air supply.
1. Attach the plug-in hose nipple (Fig. 2, item 3) to the
maintenance unit (Fig. 2, item 2).
2. Connect the compressed air supply to the mainte-
nance unit of the EPS 118 (Fig. 2, item 2).
|
1 689 989 300
2018-05-24
6.4
Filling the tank with test oil
1. Remove the screwed drain plug from the test oil filler
port (Fig. 3, item 9).
!
If the test oil is poured in too quickly, it may run out
at the filler port. Immediately clean up test oil spills
with a cloth.
!
Only fill the EPS 118 with test oil according to
ISO 4113. Never use diesel fuel.
!
The test oil level must be both above the mark of
the oil level indicator (Fig. 1, item 4) and within the
sight glass. If the test oil level cannot be seen in the
within the sight glass, too much test oil has been
filled, which will distort the measured values.
2. Pour test oil (ISO 4113) through the funnel very
slowly and carefully into the test oil filler port
(Fig. 3, item 9). Pour in test oil until it is above the
mark on the oil level indicator (Fig. 11, item 4) (ap-
proximately 4,5 l test oil).
3. Screw the screwed drain plug on to the test oil filler
port (Fig. 3, item 9) and tighten by hand.