5.4.9
Hose assemblies
!
When positioning the hose assemblies, e.g. on the
work surface, always ensure that the area is clean.
Every time before connecting the hose assembly to
the CRI/CRIN or piezo CRI, always make sure the
hose connections are clean.
i
All hose assemblies have a preinstalled strainer.
They collect contaminants which may appear during
testing despite cleaning the CRI/CRIN or piezo CRI.
They are used in the hose assemblies for the test
oil return and the hose assembly for the injection
chamber.
!
Change the strainer in regular intervals (see main-
tenance intervals in chapter 8.2.1). If the strainer is
not changed in time, it might break under increasing
dynamic pressure. Any dirt building up will no longer
be stopped from entering the system and damaging
components.
Hose assembly 1 684 462 570 and hose fitting
The hose assembly 1 684 462 570 (Fig. 9, item 1)
connect the injector return to the test connection for
the return quantity (see Fig. 3, item 3). Different hose
fittings are available for connecting the hose assembly
to different types of injectors (see Fig. 9). These are
inserted into the hose assembly before connecting to
the injector.
For certain CRIN from Bosch, the "CRIN adapter with
check valve" (Fig. 9, item 9) must be used as well. It is
inserted into the test connection for the return quantity
(CRI/CRIN, piezo CRI; see Fig. 3, item 3) prior to start-
ing the test and then connected to the hose assembly
1 684 462 570 (Fig. 9, item 1).
i
After the CRIN is selected, whether or not the "CRIN
adapter with check valve" (Fig. 9, item 9) is needed
for the test is displayed in the EPS 118 software.
!
If the "CRIN adapter with check valve"
(Fig. 9, item 9) is not used in accordance with the in-
structions or is connected incorrectly (e. g. directly
to the CRIN), a faulty measurement results, leading
to an incorrect evaluation of the CRIN.
Robert Bosch GmbH
Product description | EPS 118 | 63
2
3
4
5
6
7
Fig. 9:
Hose assembly 1 684 462 570 and hose fitting
1 Hose assembly 1 684 462 570
2 Bosch CRI hose fitting 1 681 334 034
3 Bosch CRI 2.5 hose fitting 1 681 032 119
4 Bosch CRIN hose fitting 1 683 386 192
5 Denso hose fitting 1 681 334 038
6 CRIN/Denso hose fitting 1 681 334 036
7 Delphi hose fitting 1 681 334 037
8 Strainer
9 CRIN adapter with check valve 1 683 350 904 for Bosch injectors
Included in the non-Bosch CRI accessory set 1 687 010 594
1)
(optional accessories).
i
With injectors that have a locking clamp, secure
the hose assembly 1 684 462 570 with the locking
clamp.
Hose assembly 1 684 462 569
The hose assembly 1 684 462 569 connects the Bosch
piezo CRI test oil return to the return quantity test con-
nection (Fig. 3, item 3).
Fig. 10:
Hose assembly 1 684 462 569
en
1
8
458900-01_Pal
9
1)
with thread M8x1
1)
1)
458900-02_Pal
|
1 689 989 300
2018-05-24