Chapter 1
16
Accessories
Telescope
English 8930 System User Guide 2010-12
MA07445A008
Rev X
The radio frequency energy on/off switch is a press-and-release
control. It is not necessary to hold the push button down to turn
the energy output either on or off. Simply press the switch and
then release it.
The Model 8929 Hand Piece is supplied in a kit that includes the
Model 6101 Tubing System and the Model 8934 Return Electrode.
The hand piece and its attachments are supplied as a sterile
medical device. It is single-use-only, and after use it should be
disposed of in accordance with local environmental requirements.
If the generator software detects a previously used hand piece, it
automatically disables the radio frequency energy output so the
device cannot be used for ablation. The software also displays an
alert message on the display screen that notifies the user about
this condition.
Caution: The Model 8929 Hand Piece is intended for
single-use only. Do not attempt to reuse this ablation device.
Attempting to resterilize the hand piece may cause damage to
the device rendering it unsafe for further use. Multiple uses
can result in the occlusion of the irrigation and needle
openings, which can affect the device's performance.
See Table 6-2 "Model 8929 Hand Piece Specifications" on
page 97 for limitations of proper device operation.
The Model 8099 Telescope is used with the Model 8929 Hand
Piece to provide endoscopic visualization during the Prostiva RF
Procedure. The telescope consists of an ocular sense assembly
with a 0° angle of view, and a fiber-optic light cable connector. The
telescope must be clean and sterilized before each use.
c The Model 8099TU15 telescope is used with the Model
8929 Hand Piece to provide endoscopic visualization during the
Prostiva RF Procedure. The telescope consists of an ocular sense
assembly with a 15° angle of view, and a fiber-optic light cable
connector. The telescope must be clean and sterilized before
each use.
Refer to the appropriate telescope Instructions for Use for a
detailed description of the telescope handling, cleaning, and
sterilization. Additional information is included in the Prostiva RF
Therapy Kit Model 8929 Instructions for Use.