EN PSB12-40-24-12-80
Slide the DIP switches to the position shown in the table below to set the charging program for the respec-
tive type of house battery.
Table 10: Charging curve configuration
DIP switch po-
sition (gray)
20
Max. voltage (U
Charging-
program
12 V
Lead gel
14.2 V
batteries
Wet batteries
14.4 V
AGM/1
14.7 V
batteries
AGM/2
14.7 V
batteries
LiFePO4/1
14.5 V
batteries
LiFePO4/2
14.5 V
batteries
LiFePO4/3
14.2 V
batteries
LiFePO4/4
14.2 V
batteries
Function
)
Float voltage (U
abs
24 V
12 V
28.4 V
13.5 V
28.8 V
13.8 V
29.4 V
13.6 V
29.4 V
13.6 V
29 V
13.8 V
29 V
OFF
28.4 V
13.6 V
28.4 V
OFF
)
Max. desulfation voltage
float
24 V
12 V
27 V
OFF
27.6 V
OFF
27.2 V
OFF
27.2 V
15.6 V
27.6 V
OFF
OFF
OFF
27.2 V
OFF
OFF
OFF
24 V
OFF
OFF
OFF
31.2 V
OFF
OFF
OFF
OFF