Troubleshooting
44
Errors Dialogs
Export of user list failed!
0524
Please try again.
0525
Barcode could not be read
Import failed!
0526
Multiple test type packages detected.
Please check USB key and try again.
No test type package found!
0527
Please check USB key contents and try
again.
A maximum of 50 test types can be
0528
imported onto the instrument!
Please edit the test types package
Test types package import failed!
0529
Please try again.
SD card not found!
0530
The instrument will reboot.
Please refer to user manual.
Control status has failed!
0532
Please update the control
status.
Exposure calibration failed!
0533
Please try again.
Normalisation failed!
0534
Please try again.
Instrument check has failed!
0535
Please run a new instrument check.
Self test has failed!
0536
Testing is locked out.
Please refer to user manual.
{0} instrument exposure calibration has
0539
not been completed.
Please refer to user manual.
Input invalid. Input must be between 1 and
0546
20 characters.
The export of the user list failed. Please check that the
USB key is correctly connected to the instrument and re-
attempt export.
The instrument was unable to read an internal barcode
from a carrier/cartridge. The instrument will not permit the
test to proceed.
The instrument has detected that there is more than one
test types package available for import on the attached
USB key. Remove one of the test types packages from the
USB key then re-attempt import.
If no Test types are loaded onto the instrument then a Test
Type Package must be imported onto the instrument from
an attached USB Flash memory key.
The test types package the user is attempting to import is
too large. Please contact the supplier.
The supplier must ensure that test types package provided
to the end user contains less than 50 tests.
The instrument was unable to import the Test Types from
an attached USB Flash memory key. Please ensure that the
file is placed correctly in the main file directory and the file
name correct. Ensure that only a single test type package is
located on the USB key.
The Actim 1ngeni instrument cannot find the external SD
memory card.
The instrument will not boot up.
Arrange for the return of the instrument.
The control status for the selected test type has failed.
Please run a new control test for that test type to update
the control status to pass.
The attempt made to calibrate the Actim 1ngeni
instrument has failed. Please re-attempt calibration. If this
does not correct the issue then contact the manufacturer.
The attempt made to normalise the Actim 1ngeni
instrument has failed. Please re-attempt normalisation. If
the problem persists, replace the normalisation strip. If this
does not correct the issue then contact the manufacturer.
The user may not* be able to run a test until the instrument
check test has passed.
Run a new instrument check to update the instrument
check status to Pass.
*Instrument check functionality is configurable and the
settings may vary.
The instrument self test has failed and testing has been
locked out. Run a new self test to confirm, then refer to the
recorded failure as to what has failed.
{0} displays either Visual or Fluorescent.
The instrument has not been exposure calibrated yet.
Please contact the administrator to complete the exposure
calibration process.
The text input by the user does not meet the requirements
of being between 1 and 20 alphanumeric characters.