Testing Operating Temperature of Thermostat
1) Place a thermostat and a thermometer in water and heat
the water.
2) Check to see if the thermostat begins to open at 80.5 to
83.5°C (176.9 to 182.3°F).
3) Check to see if the thermostat opens fully around 95°C
(203°F).
4)
If the measurement is defective, replace the thermostat.
at
thermostat should
start to open
80.5 to 83.5°C
176.9 to 182 .3
0
F
o
Checking and Adjusting Fan Belt Tension
1) Check to see if the belt tension allows a depression of the
specified amount when the belt is pressed down by a
finger midway between the fan drive pulley and the
dynamo pulley.
2) Adjust the tension by moving the dynamo.
Reference value
to9 mm
to 0.3543 in.l
the belt is pressed down with pressure of
to 7 kgf .• 13.2 to 15.4 IbJ