8 Störung und Abhilfe
ADM3 fault
ADM3
code (J1939)
fault code
SPN / FMI
(K-line)
729 / 12
-
730 / 0
13900
730 / 1
13901
730 / 2
13902
730 / 3
13903
730 / 4
13904
870 / 3
-
870 / 3
-
870 / 4
-
870 / 4
-
870 / 5
-
904 / 9
18809
904 / 19
18819
925 / 3
-
925 / 4
-
973 / 9
18909
973 / 19
18919
974 / 2
14202
974 / 3
14203
974 / 4
14204
986 / 1
-
986 / 9
-
986 / 9
-
1004 / 3
14403
1004 / 4
14404
1005 / 3
14503
1005 / 4
14504
ADM3 operating manual rev. 10.00b
Kapitel 8
Störung und Abhilfe
MR2
fault code
Fault location
(K-line)
Intake Air Heater
16432
(PLD/MR2)
-
Output Relay 2 (REL 2)
-
Output Relay 2 (REL 2)
-
Output Relay 2 (REL 2)
-
Output Relay 2 (REL 2)
-
Output Relay 2 (REL 2)
14223
SCR Diffusor Heating
Heater Regeneration
14270
System
14222
SCR Diffusor Heating
Heater Regeneration
14269
System
14221
SCR Diffusor Heating
-
Front Axle Speed
-
Front Axle Speed
SCR Module Proportional
17905
Valve Bank
SCR Module Proportional
17908
Valve Bank
Engine Retarder
-
Selection
Engine Retarder
-
Selection
Remote Throttle Pedal
-
(HFG)
Remote Throttle Pedal
-
(HFG)
Remote Throttle Pedal
-
(HFG)
10631
Fan Speed
10612
Fan Speed
17112
Fan Speed
-
Output Relay 4 (REL 4)
-
Output Relay 4 (REL 4)
Output PWM Pedal
-
Supply or Transmission
(FP+)
Output PWM Pedal
-
Supply or Transmission
(FP+)
Fault description
Circuit Universal Troubles
Grid Heater: No
Increasing Boost
Temperature After
Activation
Relay Permanently
Closed (Grid Heater)
Relay Permanently Open
(Grid Heater)
Voltage too High when
Activated
Voltage too Low when
Activated
Circuit High
Circuit High
Circuit Low
Circuit Low
Circuit Open
Abnormal Update Rate
Received Network Data
in Error
Circuit High
Circuit Low
Abnormal Update Rate
Received Network Data
in Error
Supply Voltage Out of
Range (Pin HFG+)
Voltage too High
Voltage too Low
Speed Too Low
Time Out
Time Out
Open Circuit
Short Circuit to Ground
Open Circuit
Short Circuit to Ground
354
9. Fault codes
Remedial action
- Check wiring
- Check relay 2
- Check grid heater
- Check wiring
- Check relay 2
- Check wiring
- Check relay 2
- Check wiring
- Check wiring
- Check relay 2
- Limit values for the supply
voltage of the
HFG:
Minimum value: 4,8 V and
maximum value: 5,2 V.
- Check wiring
- Check remote pedal
- Check wiring
- Check remote pedal
- Check wiring
- Check relay 4
- Check wiring
- Check relay
- Check wiring.
- Check wiring.
Pin
LSCAN-
MR
15/09
15/09
15/09
15/09
15/09
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
CAN-
J1939
CAN-
J1939
LSCAN-
MR
LSCAN-
MR
CAN-
J1939
CAN-
J1939
18/17
18/18
18/18
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
18/01
18/01
15/05
15/05
161 / 226