Herunterladen Diese Seite drucken

Ropa euro-Maus 4 Originalbetriebsanleitung Seite 352

Werbung

8 Störung und Abhilfe
ADM3 fault
ADM3
code (J1939)
fault code
SPN / FMI
(K-line)
655 / 12
-
655 / 14
-
656 / 5
-
656 / 6
-
656 / 7
-
656 / 12
-
656 / 14
-
657 / 5
-
657 / 6
-
657 / 7
-
657 / 12
-
657 / 14
-
658 / 5
-
658 / 6
-
658 / 7
-
658 / 12
-
658 / 14
-
677 / 3
-
677 / 3
13303
677 / 4
13304
677 / 5
-
677 / 6
-
677 / 7
-
677 / 14
-
697 / 3
-
697 / 3
-
697 / 4
-
697 / 5
-
697 / 5
-
697 / 6
-
ADM3 operating manual rev. 10.00b
Kapitel 8
Störung und Abhilfe
MR2
fault code
Fault location
(K-line)
19444
Injector Cylinder 5
19445
Injector Cylinder 5
15527
Injector Cylinder 6
15528
Injector Cylinder 6
15526
Injector Cylinder 6
19544
Injector Cylinder 6
19545
Injector Cylinder 6
15627
Injector Cylinder 7
15628
Injector Cylinder 7
15626
Injector Cylinder 7
19644
Injector Cylinder 7
19645
Injector Cylinder 7
15727
Injector Cylinder 8
15728
Injector Cylinder 8
15726
Injector Cylinder 8
19744
Injector Cylinder 8
19745
Injector Cylinder 8
Output Relay 1
18005
(PLD/MR2)
-
Output Relay 1 (REL 1)
-
Output Relay 1 (REL 1)
Output Relay 1
18009
(PLD/MR2)
Output Relay 1
18008
(PLD/MR2)
Output Relay 1
18086
(PLD/MR2)
Output Relay 1
18033
(PLD/MR2)
17007
Proportional Valve 1
Proportional Valve
17705
Bank 1
Proportional Valve
17708
Bank 1
Proportional Valve
12425
Bank 1
17009
Proportional Valve 1
17006
Proportional Valve 1
Fault description
Idle Control At Limit
Cylinder Correction At
Limit
Open Circuit
Shorted Circuit
Injection Timing, No
Plunger
Idle Control At Limit
Cylinder Correction At
Limit
Open Circuit
Shorted Circuit
Injection Timing, No
Plunger
Idle Control At Limit
Cylinder Correction At
Limit
Open Circuit
Shorted Circuit
Injection Timing, No
Plunger
Idle Control At Limit
Cylinder Correction At
Limit
Starter Relay Shorted To
High
Open Circuit
Short Circuit to Ground
Starter Relay Open
Circuit
Starter Relay Shorted To
Ground
Starter Stick, Does not
Engage
Starter Relay Stick
Circuit High
Shorted To Battery
Voltage Bank 1
Shorted To Ground
Bank 1
Open Circuit
Open Circuit
Shorted To Ground
352
9. Fault codes
Remedial action
- Check wiring
- Check relay 1
- Check wiring
- Check relay 1
Pin
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
15/12
15/12
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
LSCAN-
MR
159 / 226

Werbung