Chapter 7 Operation
EVENT COUNTER
A number of different "event counters" can be queried using this function. These provide use-
ful statistical information about events which are counted automatically while the labeler is
running.
Event
E00
E01 to E22
7
*
All counter values are stored in the non-volatile memory of the labeler. The counter values
are stored at the time of a fault or in stand-by mode. This means, if the system is switched off
in the "READY" mode, the counter values EV1 EV5 can differ greatly from the actually
counted values.
Press the [] or [] *buttons to switch to the next parameter.
Press [Enter] to go to the event counters.
[]
[]
Press the [] or [] buttons to go to the next event counter.
To exit the parameter settings please press [Start] or [Stop] respectively.
Version: 23.04.2018
Counter information
Number of all stopped application cycles without failure.
Number of faults that have occurred under the corresponding error code (see
page 72 ff).
5 digit counter,
Maximum value = 65535
(afterwards start at 00000)
8 digit counter,
Maximum value: 99999999
(afterwards start at 00000000)
Page 53 of 76
*Fast forward function when the [] or [] button is held down.