Herunterladen Diese Seite drucken

TR-Electronic EtherCAT C V582 EtherCAT C H582 Bedienungsanleitung Seite 90

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Commissioning
5 Commissioning
5.1 Device description file
With each EtherCAT device a device description file, the so-called "EtherCAT Slave
Information" - File (ESI) must be delivered. The file is provided in XML and contains all
information on the measuring system-specific parameters and the operating modes of
the measuring system. The XML file is integrated by the EtherCAT network
configuration tool, in order to enable correct configuration and commissioning of the
measuring system.
The XML file is called "TR-Ethercat_Cxx2M_xx_FoE.xml".
Download:
www.tr-electronic.de/f/TR-ECE-ID-MUL-0053
5.2 Bus status display
The EtherCAT measuring system is equipped with four diagnostic LEDs. Position and
allocation of the LEDs have to be taken from the enclosed pin assignment!
Indicator states and flash rates
Figure 5: Indicator states
Link / Activity IN+OUT - LED Description
Color
ON
Flickering = Data Activity
 TR-Electronic GmbH 2016, All Rights Reserved
Page 90 of 143
green
= Link
Ethernet connection established
IN
OUT
TR - ECE - BA - DGB - 0127 - 04
= Data transfer RxD,
= Data transfer TxD
Printed in the Federal Republic of Germany
06/20/2017

Werbung

loading

Diese Anleitung auch für:

Ethercat c s582