Manufacturer and Profile Specific Objects (CiA DS-406)
8.6 Object 6003h: Preset value
The Preset Function can be used to adjust the measuring system to any position value
within a range of 0 to measuring length in increments –1. With the writing to the object,
the output position value is set without this having to be confirmed to in addition.
Index
Description
Data type
Category
Access
PDO mapping
Value
Activation/Storage
In order to ensure a safe acceptance of the parameters
 Counting direction
 Scaling parameters
changes must be first taken over and stored by means of "Object 1010h: Store
Parameters". In a further step the new Preset value can be written.
If storing could be completed successfully, the current preset value is verified. If it is
larger than the programmed measuring length, the preset value is adjusted to the new
measuring length.
Now, in another step the desired preset value can be written.
 TR-Electronic GmbH 2016, All Rights Reserved
Page 124 of 143
Risk of injury and damage to property by an actual value jump when the
Preset adjustment function is performed!
 The preset adjustment function should only be performed when the
measuring system is at rest, otherwise the resulting actual value jump must
be permitted in the program and application!
0x6003
Preset Value
UNSIGNED32
Mandatory
rw
No
current position, or a value within the range from 0 to
programmed measuring length in steps – 1
with write access
Byte 0
Byte 1
7
0
15
2
to 2
2
(Object 0x2001 or 0x6000) and the
(Objects 0x2002, 0x2003, 0x2004 or 0x6001, 0x6002)
TR - ECE - BA - DGB - 0127 - 04
Preset value
Byte 2
8
23
to 2
2
to 2
Byte 3
16
31
24
2
to 2
Printed in the Federal Republic of Germany
06/20/2017