8.11 Measuring system diagnostics
8.11.1 Object 6500h: Operating status
The object 6500h "Operating status" contains the operating status and information
about the internal programmed parameters.
Index
Description
Data type
Category
Access
PDO mapping
Bit
0
1
2
3 - 15 reserved
8.11.2 Object 6501h: Single-Turn resolution
The object 6501h contains the number of measuring steps per revolution which can be
output by the measuring system.
Index
Description
Data type
Category
Access
PDO mapping
Upper limit
Standard value: 4096 = 1000h steps per revolution (depending on capacity marked
Printed in the Federal Republic of Germany
06/20/2017
0x6500
Operating Status
UNSIGNED16
Mandatory
ro
No
Function
code sequence
reserved
scaling parameters are used
0x6501
Singleturn Resolution
UNSIGNED32
Mandatory
ro
No
device specific (max. value see nameplate)
Byte 0
Byte 1
7
0
15
2
to 2
2
on nameplate).
TR - ECE - BA - DGB - 0127 - 04
Single-Turn resolution
Byte 2
8
23
to 2
2
to 2
Bit = 0
Bit = 1
increasing
decreasing
-
Yes
Byte 3
16
31
24
2
to 2