Installation / Preparation for Commissioning
4.1 Connection
Pin
1
2
3
4
Pin
1
2
3
4
Pin
1
2
3
4
Shielded twisted pair cables must be used for the supply!
The shielding is to be connected with large surface on the mating
connector housing!
Position and allocation of the connectors have to be taken from the enclosed
pin assignment!
Order numbers for the Ethernet connector, suitably for the D-coded female socket
M12x1-4 pin.
Manufacturer
Binder
Phoenix Contact
Phoenix Contact
Harting
TR-Electronic GmbH 2016, All Rights Reserved
Page 88 of 143
PORT-IN
Female socket
TxD+
Transmission Data +
RxD+
Receive Data +
Transmission Data –
TxD–
Receive Data –
RxD–
PORT-OUT
Female socket
TxD+
Transmission Data +
RxD+
Receive Data +
Transmission Data –
TxD–
Receive Data –
RxD–
Male socket
(M12x1-4 pin. A coded)
11 – 27 V DC
Encoder-Supply Voltage
RS-485+
For service purposes only!
0 V
Encoder-Supply Voltage
RS-485–
For service purposes only!
Name
Series 825
SACC-M12MSD-4CON-PG 7-SH (PG 7)
SACC-M12MSD-4CON-PG 9-SH (PG 9)
HARAX
TR - ECE - BA - DGB - 0127 - 04
(M12x1-4 pin. D coded)
Mating
Face
(M12x1-4 pin. D coded)
Mating
Face
Mating
Face
M12-L
2
3
1
4
Art-No.:
99-3729-810-04
15 21 25 8
15 21 26 1
21 03 281 1405
Printed in the Federal Republic of Germany
06/20/2017