Herunterladen Diese Seite drucken

TR-Electronic EtherCAT C V582 EtherCAT C H582 Bedienungsanleitung Seite 138

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Perform „Adjustment on the fly"
7. If the measuring system is now switched to OP mode, the process data are visualized
as follows in the figure:
a. Position value with the actual position value
b. Adjustment status with the value 0
c. Adjustment position with the actual value 0
d. Adjustment control with the actual value 0
8. The value "Adjustment position" can be set to a new value using the "Online Force"
functionality as shown in the following figure. This is followed by a dialog in which the
new value is entered. As soon as this dialog is closed by means of the "OK" button,
the value of the object 0x5004 also changes in the object directory. In the specific
case, the value 7000 can be seen.
 TR-Electronic GmbH 2016, All Rights Reserved
Page 138 of 143
TR - ECE - BA - DGB - 0127 - 04
Printed in the Federal Republic of Germany
06/20/2017

Werbung

loading

Diese Anleitung auch für:

Ethercat c s582