Herunterladen Inhalt Inhalt Diese Seite drucken

Limited Warranty - Medtronic Affinity CP BBAP40 Gebrauchsanweisung

Zentrifugalblutpumpe mit balance biosurface
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 64
800
700
600
500
400
1
300
200
100
1500
a
1000
0
0
2
Figure 8. Hydraulic performance of the Affinity CP centrifugal blood pump

15. LIMITED WARRANTY

The following LIMITED WARRANTY applies to United States customers only:
A. This LIMITED WARRANTY is available solely to the original purchaser of the Medtronic Affinity™ CP Centrifugal Blood Pump
with Balance™ Biosurface, Model BBAP40 (hereinafter, referred to as "Product").
(1) In the event that the Product fails to function within normal tolerances due to a defect in materials or workmanship within
a period of one (1) year, commencing with the delivery of the Product to the purchaser, Medtronic will at its sole option:
(a) repair or replace any defective part or parts of the Product; (b) issue a credit to the purchaser equal to the Purchase
Price (as defined in Subsection A(2) below) against the purchase price of the replacement Product; or (c) provide a
functionally comparable replacement Product at no charge.
(2) As used herein, Purchase Price shall mean the lesser of (i) the net invoiced price of the original Product, (ii) the price of
currently functional comparable equipment, or (iii) the price of replacement equipment.
B. To qualify for the repair, replacement or credit set forth in Section A above, the following conditions must be met:
(1) The Product must be returned to Medtronic within sixty (60) days after discovery of the defect;
(2) The Product must not have been used other than in strict accordance with the Instructions for Use, must not have been
used on more than a single patient, and must not have been altered or repaired in any way which, in the judgment of
Medtronic, affects the stability and reliability of the Product. The Product must not have been subjected to misuse, abuse
or accident; and
(3) The "Use-by Date" for the Product must not have passed.
C. This LIMITED WARRANTY is limited to its express terms. In particular:
(1) Except as expressly provided by this LIMITED WARRANTY, MEDTRONIC IS NOT RESPONSIBLE FOR ANY DIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES BASED ON ANY DEFECT, FAILURE OR MALFUNCTION OF THE
PRODUCT, WHETHER THE CLAIM IS BASED ON WARRANTY, CONTRACT, TORT OR OTHERWISE.
(2) This LIMITED WARRANTY is made only to the purchaser of the Equipment. AS TO ALL OTHERS, MEDTRONIC MAKES
NO OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHETHER ARISING FROM STATUTE,
COMMON LAW, CUSTOM OR OTHERWISE. NO EXPRESS OR IMPLIED WARRANTY TO THE PURCHASER SHALL
EXTEND BEYOND THE PERIOD SPECIFIED IN A(1) ABOVE. THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE
REMEDY AVAILABLE TO ANY PERSON.
D. The exclusions and limitations set out above are not intended to, and should not be construed so as to contravene mandatory
provisions of applicable law. If any part or term of this LIMITED WARRANTY is held to be illegal, unenforceable or in conflict
with applicable law by a court of competent jurisdiction, the validity of the remaining portions of the LIMITED WARRANTY
shall not be affected, and all rights and obligations shall be construed and enforced as if this LIMITED WARRANTY did not
contain the particular part or term held to be invalid.
E. No person has any authority to bind Medtronic to any representation, condition or warranty except this LIMITED WARRANTY.
a
3000
a
2500
a
2000
a
4
6
8
2
1. Pressure drop (mm Hg)
a
2. Flow rate (LPM)
4000
3.
a
= RPM
a
3500
10
12
Instructions for Use
English
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis