Herunterladen Inhalt Inhalt Diese Seite drucken

Jungheinrich DFG 316s Betriebsanleitung Seite 156

Hubhöhe (standardteleskopmast) 2900-7500 mm
Vorschau ausblenden Andere Handbücher für DFG 316s:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replace fuel filter
– Drain fuel from the filter into a
suitable container.
– Loosen fuel filter (65) with a filter
wrench and unscrew by hand.
Qw W
Properly dispose of fuel and
fuel filter.
– Screw fuel filter back on with new O-
ring.
– Lightly moisten O-ring with diesel
fuel before installation.
– Clean seal surfaces and filter flange
thoroughly.
– Lightly moisten the new fuel filter's
seal with diesel fuel.
– Screw on the fuel filter by hand until
the seal contacts the filter flange.
– Tighten the fuel filter one-third rotation further.
– Bleed fuel system.
Bleeding the fuel system
Qw W
Collect
properly dispose of it.
– Open bleeder screw (66).
– Actuate the hand pump lever on the
fuel pump (67) until fuel comes out
on
the
bubbles.
– Tighten bleeder screw.
– Turn
ignition/starter
position I for approx. 10 s.
– Wait 10 s.
– Repeat until engine starts.
IMPORTANT Check the fuel filter, overflow
valve and fuel injector cap
units for leaks during the
engine test run.
NOTICE
If the engine does not start or
stalls right away, repeat the
bleeding procedure.
draining
fuel
bleeder
screw
without
switch
and
to
G 39

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tfg 316sDfg 550sTfg-550s

Inhaltsverzeichnis