Configuration
point
Alarm 2
Alarm type
Alarm / Event List
Alarm text
Limit
Hysteresis
Window width
Alarm delay. on
Alarm delay out
a
1
) The unit displayed is dependent on the operating mode. See
2
) The set temperature unit from the basic settings is displayed as a unit.

10.4.3.3 Universal inputs calibration timer

Universal input base: IN 6 Universal inputs option board: IN 11/12
Go to: Device menu è Configuration è Analogue inputs è Universal input 1è
Calibration timer
Configuration item
Function
Alarm / event list
Alarm text
Calibration interval
Selection/configuration
Inactive
Min. alarm
Max. alarm
Alarm window
Alarm window invert.
Out
alarm
event
up to 20 characters of text
-99999 to +99999
0 to 99999
0 to 99999
0 to 999 s
0 to 999 s
Selection / option
Inactive active
OFF
Event
Alarm
Text box
0 - 9999
153
Explanation
Choice of alarm type
Out: Alarm is not displayed
Alarm: Alarm is displayed in the
alarm bar of the display
Event: Al is only displayed in the
event list
Text which is displayed when an
alarm is in the display and/or is on
the event list.
For the limit value, an alarm is
triggered by an excess or underflow
(depending on the type of alarm)
Distance from the threshold
Alarm on =
< Thresh. - Hyst. (At minimum
alarm)
> Thresh. + Hyst. (At max. alarm)
Alarm =
> Limit (at minimum alarm)
<Limit (at max. alarm)
Width of the alert window (in case
of alarm type "alarm window") or in
which no alarm is triggered the
window, (at the alarm type "inverted
Alarm window")
Time delay between occurrence of
the alarm condition and the alarm
turning on
Time delay between end of the
alarm set to on and the alarm
turning off
Ä Chapter 10.4.2 'Basic settings' on page 148.
Explanation
Enable calibration timer
OFF: No entry
Event: At the end of the
calibration interval, the
text, "Alarm Text" is
written in the event list.
Alarm: At the end of the
calibration interval, the
text "Alarm Text" is written
in the display list.
Text shown as alarm text
Time after which a
calibration request is
displayed
Device menu
Default
inactive
Alarm
Alarm 2 Temp.
Input 1
0,00
0,00
0,00
0 sec
0 sec
Default
Inactive
Event
Request cal. Ch. X
10 days