10.4.13 Ethernet

The Ethernet settings must be obtained from the administrator of the network in which the
device is to be installed.
Go to: Device menu è select configuration è select basic settings
Configuration
point
IP address
assignment
Man. IP address
Subnet mask
Default gateway
DNS device name
DNS server
Transfer rate
(
1
) To manually enter an IP configuration for the Ecolab 'Versatronic' , a valid free IP address of the network must be known. For this
purpose, consult with your network administrator.
In the Ecolab PC Setup program the Ethernet settings are set in the online
parameters.
From the PC, the IP configuration of the device can also be changed if PC
and device are connected via Ethernet. In this case, changing the IP
address or subnet mask can end the PC/device connection.
See

10.4.14 Serial interfaces

The settings of the serial interfaces of all subscriber devices on a bus must match.
Go to: Device menu è Configuration è Serial interfaces è Serial interfaces 1 to 2
Configuration item Selection / option Explanation
Protocol
Baud rate
Data format
Minimum response
time
Device address
Selection / option
Manual
Automatic
valid IP address (1)
valid subnet mask (1)
valid IP address (1)
DNS name device name
Valid IP address (1)
Automatically
10 Mbit / s half-duplex
10 Mbit / s full duplex
100 Mbit / s half-duplex
100 Mbit / s full duplex
Ä Chapter 12.7 'Connecting to the device' on page 198.
Modbus slave
9600
19200
38400
8 - 1 - no parity
8 - 1 - odd parity
8 - 1 - even parity
0 to 500 ms
1 to 254
Explanation
Manual:
If no DHCP server is installed on the
network and the IP address configuration
is known (e.g. for a network
administrator), enter the data manually.
Automatic: The network has a DHCP
server installed. At power up and startup,
Ecolab 'Versatronic' receives the IP
configuration from the DHCP server; IP
configuration is automatic.
IP configuration of the Ethernet option
board
Manual entry of known configuration
data, or automatic configuration by
DHCP server (see Configuration item
"Issue IP address")
Transmission speed (bit rate) and duplex
mode of the Ethernet option board
This setting must match the setting of
the switch or router ports to which the
Ecolab 'Versatronic' is connected.
Communication protocol
Transmission rate (symbol rate) of the serial
interface
Format of the data word
Useful bits - stop bits - Parity
Minimum period from the reception of a query
to the sending of a reply
This parameter is used to adjust the response
speed of the device to slower bus users.
Unique identifier of a bus subscriber
175
Device menu
Default
Automatic
223 . 223 . 223 . 1
255 . 255 . 255 . 1
0 . 0 . 0 . 0
0 . 0 . 0 . 0
Automatic
Default
Modbus slave
9600
8 - 1 - no parity
40 ms
1
417102269 Rev. 2-08.2020