Chapter 1. Controls
Master power switch (
switch off (
) while a formula is running, the immediate result is similar to pressing the
m
emergency stop button: the machine stops and the drain opens. Unlike the emergency stop
button, resumed formulas start at the beginning of the step in which power was lost, but
chemicals are not injected in the resumed step.
Operator signal cancel button (
buzzer and turn off the operator signal light (see below), or to allow injection of a chemical
programmed to require a signal before injection.
Operator signal light—indicates that the machine has encountered an error or that the operator
must perform some action, such as pressing the start button or unloading the machine. The
operator signal circuit includes a buzzer behind the control panel, and may include an optional
beacon light mounted separately from the control panel.
Liquid crystal graphic display—displays information and help about the machine. The
information on the display changes according to the status of the machine and the function
selected by the operator.
Keypad—allows the operator to communicate with the machine control system. The keypad is
divided into three areas: alphanumeric buttons, general buttons, and function-specific buttons.
Each button may perform more than one function, based on the current machine status. Some
buttons are also used in combinations for additional functions.
Start button (
)—starts the selected wash formula. The start button energizes the 3-wire circuit
1
to allow the machine to operate.
Stop button (
)—stops machine operation. Like the emergency stop button, the stop button
0
disables the 3-wire circuit; however, the stop button doesn't require you to manually reset it
after use.
Run/Program keyswitch (
configuration and wash formulas, among other actions. In the normal Run position, formulas
and configuration are protected and formulas can be run.

What does this Switch do?

1.1.4.
Other buttons and switches are used to control additional standard and optional machine
functions. These miscellaneous controls are located and described in this section.
Mildata/Local selector switch
Figure
1), allows the machine to communicate with a Mildata network. A Mildata network
connects several machines together and allows them to share wash formulas and other data
with the Mildata computer. When this switch is in the Mildata position (
formula number, the machine requests the contents of the formula from the Mildata computer.
When set to the Local position (
Figure 6: Mildata/Local Selector switch
Manual supply flush button
supply injector, press this button to spray water into the supply injector to flush any remaining
PELLERIN MILNOR CORPORATION
/
)—removes power from the control system. If you turn the master
m
M
)—cancels the operator signal. Press this button to silence the
A
/
)—in the Program position, allows changes to machine
R
P
(Figure
6)—located on the microprocessor control box (see
), only formulas present in the machine are available.
_
(Figure
7)—On machines equipped with an optional flushing
10