Figure 4: Keypad
Figure 5: Typical Staph Guard Clean Side Controls
Control Panel
.
Emergency stop button—disables the 3-wire circuit. This switch locks in when pressed, so you
must turn it a quarter turn to allow it to return to the normal position to allow the machine to
run.
Notice 1 : Press the emergency stop button immediately in any emergency situation. This
disables the 3-wire circuit, which stops all machine operation and causes the drain to open.
• When you reset this button, you have the option of cancelling or resuming the interrupted
formula. The formula resumes where it was interrupted or at the beginning of the previous
bath step, depending on the operation in progress when the emergency stop button was
pressed.
Legend
A.
Emergency stop button
B.
Door unlock button
C.
Jog/Autospot selector switch
D.
Control on clean side indicator
E.
Control on soil side indicator
F.
Control transfer button
G.
Jog/spot button
9
Chapter 1. Controls
PELLERIN MILNOR CORPORATION