Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Delivery; Optional Equipment And Accessories; Technical Data; Electrical System - Reflex Servitec 35 Originalbetriebsanleitung

Control touch steuerung
Vorschau ausblenden Andere Handbücher für Servitec 35:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Servitec 35 - 95 with motorized ball valve
1
Control line of a pressure maintenance station for requesting the make-
up in "Levelcontrol" mode
Signal line from the "PIS" pressure transducer for the "Magcontrol"
2
make-up variant
3
"DC" degassing line (degassed water)
4
"DC" degassing line (gas-rich water)
5
"WC" make-up line
6
Optional equipment and accessories  4.5 "Optional equipment and
accessories",  29
7
Control Touch controller
4.4

Scope of delivery

The scope of delivery is described in the shipping document and the content is
shown on the packing.
Immediately after receipt of the goods, please check the shipment for
completeness and damage. Please notify us immediately of any transport
damage.
5

Technical data

Note!
The following values apply for all systems:
Permissible operating temperature of the device:
Permissible inlet pressure for make-up:
Make-up capacity:
Separation level, dissolved gases:
Separation level, free gases:
Degree of protection:
5.1

Electrical system

Type
Power output
(kW)
35
0.85
60
1.1
75
1.1
95
1.1
5.2

Dimensions and connections

Type
5
60
75
95
Power supply
(V / Hz/ A)
(internal)
230 / 50
230 / 50
230 / 50
230 / 50
Weight
Height
(kg)
(mm)
30
965
36
1150
41
1150
42
1150
Vacuum spray degassing — 18.12.2019-Rev. A
Basic degassing equipment:
Control of the Servitec.
"DV" degassing valve, box-packaged.
Plastic sleeve with operating manual and electric wiring diagram (attached
to the Servitec).
The Servitec is pre-assembled and shipped on a pallet.
4.5

Optional equipment and accessories

The following optional equipment and accessories are available for this device:
Fillsoft/Fillsoft zero for softening/desalination of the make-up water from
the potable water supply system. Replacement of the softening and
desalination cartridges.
Fillset for make-up with water
Fillset with integrated backflow preventer, water meter, dirt trap,
and shut-ff for the "WC" make-up line
Fillset Impulse with FQIR+ contact water meter for make-up with water.
If the Fillset Impulse is installed, you can regulate the entire make-up
quantity and the soft water capacity of Fillsoft softening systems. The
operational reliability of the device is assured and prevents
automatic make-up during major water loss or small leaks.
Fillset Compact for make-up
Fillset Compact with integrated system separator, dirt trap, and shut-
off for the "WC" make-up line.
Fillguard for conductivity monitoring
If the Fillguard is fitted, the capacity of the Fillsoft Zero desalination
cartridge can be monitored based on the conductivity.
Enhancements for the device controller.
Various controller information can be queried via the RS-485
interface and it can also be used to communicate with control
centres or other devices,  6.5.3 "RS-485 interface",  34.
Gas discharge measurement for optimised degassing operation.
Note!
Separate operating manuals are supplied with accessories.
90 °C
1.3 bar – 6 bar
Up to 0.55 m³/h
≤ 90 %
100 %
IP 54
Fusing
Number of RS-485
interfaces
(A)
10
2
10
2
10
2
10
2
Width
(mm)
553
600
573
573
Bus modules for the communication with control centres.
Profibus-DP.
Ethernet.
I/O module for standard communication.
Modbus RTU
Control Remote
I/O module
Control Unit
(V, A)
Optional
230, 2
Optional
230, 2
Optional
230, 2
Optional
230, 2
Depth
Servitec input
(mm)
connections (system
and make-up)
486
Internal thread ½ "
486
Internal thread ½ "
635
Internal thread ½ "
635
Internal thread ½ "
Technical data
Noise level
(dB)
55
55
55
55
Servitec output
connection
Internal thread 1 "
Internal thread 1 "
Internal thread 1 "
Internal thread 1 "
English — 29

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Servitec 60Servitec 75Servitec 95

Inhaltsverzeichnis