Internal operation
●
During this calibration, plain paper loads on the drum and a calibration pattern prints. The Tetris
sensor (SN58) scans the pattern to determine the x and y locations of the first black nozzle printing
position. This calibration also occurs automatically as part of the APA calibration process.
Instructions
ACHTUNG:
this calibration.
▲
See
„Engine Calibrations 1" auf Seite
DEWW
This calibration is light-sensitive. All of the MFP covers must be installed before you run
Top-of-form sensor (SN22) and Tetris sensor (SN58) calibrations 165
58.