Drum calibrations
Drum Position calibration
Drum Position calibration
Purpose
This calibration determines the relative position of the drum calibration holes to the drum encoder
disk.
When to run
Run this calibration after the drum encoder disk or a drum encoder PCA is replaced or reinstalled
after a repair procedure.
Required time
2 to 3 minutes
Internal operation
The Tetris sensor (SN58) locates precisely placed calibration holes on the drum edge surface. The
calibration holes correspond to a precise encoder disk count for this MFP. This calibration helps
determine the drum vacuum zone locations to use for loading the leading edge of the media.
Instructions
ACHTUNG:
this calibration.
See
„Engine Calibrations 1" auf Seite 58
140 Kapitel 5 Calibrations and adjustments
This calibration is light-sensitive. All of the MFP covers must be installed before you run
DEWW