Calibration
Reset Nozzle
Health Database
(NHDB)
Store NHDB
Other features on the page
Print Test: Click to open the Print Test page.
Diagnostic Plots: Click Nozzle Health or All Colors to print a diagnostic plot from the selected tray.
Use the Enable Error Hiding checkbox to turn error hiding on and off when printing these pages.
The default for Enable Error Hiding is unchecked (Error Hiding OFF).
Pen Health Gauge:
Pen Health Gauge
The Pen Health Gauge indicates the nozzle health of each pen:
Indicator status
Green (+)
Yellow (!)
Red (-)
Gray (?)
HINWEIS:
NHDB is reset, or a pen-related calibration completes.
Pen ID: Displays a dialog with the following information:
Fill date code
Pen ID
DEWW
Steps
Click Reset NHDB
Click Store NHDB
„Pen Health Gauge" auf Seite
The gauges status is refreshed anytime the Engine Calibrations 1 page is displayed, the
59.
Meaning
The pen is healthy.
The pen is functioning but might need to
be cleaned.
The pen needs to be cleaned.
HINWEIS:
If the Pen Health Gauge
indicates that a newly installed pen
needs to be cleaned, see
„Stiftstatusanzeige verweist beim
Installieren eines neuen Stifts auf
ausgefallene Düsen" auf Seite
The health of the pen is not known or the
NHDB has been reset. Run a Drop
Detect to refresh the Pen Health Gauge.
See
„Engine Calibrations 1"
auf Seite
58.
Approximate
Complete description
time
2 to 3 seconds
„Reset NHDB"
auf Seite 152
2 to 3 seconds
„Store NHDB"
auf Seite 152
Action Required
None
Never replace a pen because of yellow.
Pen cleaning only if a streak shows in
normal prints.
Pen cleaning
1059.
Run the Drop Detect routine to refresh
the Pen Health Gauge, followed by the
New Pen Servicing routine, if needed
Calibrate the MFP