Required time
10 to 11 minutes
Internal operation
This procedure uses SN58 to scan and measure a set of preprinted target pages. The target pages
have been previously scanned and the color data recorded in a data file. The data file is unique to
the target pages and must not be used with other targets. A USB thumb drive will contain the
spectral data for the calibration and is attached to the USB port near to where the networking cable
attaches.
Instructions
ACHTUNG:
this calibration.
HINWEIS:
pages that are used need to be protected from damage. Using the finisher subjects them to more
potential roller damage.
Use the Tetris Sensor calibration kit.
HINWEIS:
until needed.
a.
Check that the identifying number on the USB data drive and the number on the calibration
sheets match. If the numbers do not match then they cannot be used together for the
calibration.
b.
Insert the USB data drive into the MFP.
c.
Insert the calibrations sheets in tray 2, 3, or 4.
HINWEIS:
the proper order and correctly oriented. The top sheet should be page 1.
d.
Select the tray.
e.
Click Tetris Sensor Calibration.
First Nozzle Position calibration
Purpose
This calibration determines the location of the first black ink nozzle used for printing.
When to run
Run the calibration when the Tetris sensor (SN58) is replaced.
Required time
3 to 4 minutes
164 Kapitel 5 Calibrations and adjustments
This calibration is light-sensitive. All of the MFP covers must be installed before you run
Disconnect any attached finisher when running the calibration. The preprinted calibration
Calibration sheets can be used multiple times and should be stored flat in their packet
Each calibration sheet is numbered. Ensure that the calibrations sheets are in