Calibrate the MFP
To gain access to calibrations in CDFT, click Settings/Procedures, and then click Calibrations.
Engine Calibrations 1
Pen Health Gauge
Engine Calibrations 2
Scanner and ADF calibrations
Tray calibrations
For a full description of a calibration, see
Engine Calibrations 1
The following calibrations are run from this page:
HINWEIS:
Servicing.
Calibration
Pen Cleaning
New Pen
Servicing
Automatic Pen
Alignment (APA)
Pen Density
Compensation
Drop Detect
Drop Detect
Beam
58
Kapitel 3 Copier Diagnostic Field Tool (CDFT)
All of the following calibrations are available in the Service Assist Mode except New Pen
Steps
Click Pen Cleaning
Select New Pen Servicing
1.
Load fresh Letter or A4 plain paper in paper tray 1, 2,
3, or 4.
2.
Select the paper tray.
3.
Select Automatic Pen Alignment, and then click
Start.
4.
After the calibration completes, print the "Pen
Alignment test 8.5x11/A4" page.
1.
Load fresh Letter or A4 plain paper in paper tray 1, 2,
3, or 4.
2.
Select the paper tray.
3.
Select Pen Density Compensation, and then click
Start.
4.
After the calibration completes, print a Composite
Gray test page.
Click Drop Detect
Click Drop Detect Beam
„Calibrations and adjustments" auf Seite
135.
Approximate
Complete description
time
4.5 to 15 minutes
„Pen Cleaning routine"
auf Seite 151
10 minutes
„New Pen Servicing
routine" auf Seite 150
18 to 40 minutes
„Automatic Pen
Alignment (APA)
calibration"
auf Seite 148
12 to 15 minutes
„Pen Density
Compensation
calibration"
auf Seite 149
2 to 3 minutes
„Drop Detect routine"
auf Seite 151
2 to 3 minutes
„Drop Detect Beam
calibration"
auf Seite 149
DEWW