Herunterladen Diese Seite drucken

HP CM8060 Color MFP Kundendienst Handbuch Seite 126

Vorschau ausblenden Andere Handbücher für CM8060 Color MFP:

Werbung

HINWEIS:
last number of the year (one digit). For example, a fill date code of CMF347 would mean week 34 and
year 2007.
Engine Calibrations 2
The following calibrations are run from this page:
HINWEIS:
are available in Service Assist Mode.
Calibration
Carriage-to-
Carriage
Alignment
Carriage
Stopping
Accuracy
Carriage
Encoder Strip
Reset
Tetris sensor
(SN58)
Calibration
Reset Pen
Density
Compensation
Top-of-form
First Nozzle
Position
Drum Position
Media Side Edge
60
Kapitel 3 Copier Diagnostic Field Tool (CDFT)
The last three digits of the fill date code are the week number (two digits) followed by the
Only the Carriage Stopping Accuracy and the Carriage-to-Carriage Alignment calibrations
Steps
Click Carriage-to-Carriage Alignment
Click Carriage Stopping Accuracy.
Click Reset Carriage Encoder.
Follow the onscreen instructions. (Requires the use of the
Tetris Sensor calibration kit.)
Click Reset Pen Density Compensation.
1.
Load several sheets of fresh Letter or A4 plain paper
in paper tray 1, 2, 3, or 4.
2.
Select the paper tray.
3.
Select Top-of-Form, and then click Start.
1.
Load several sheets of fresh Letter or A4 plain paper
in paper tray 1, 2, 3, or 4.
2.
Select the paper tray.
3.
Select First nozzle position, and then click Start.
1.
Load several sheets of fresh Letter or A4 plain paper
in a paper tray.
2.
Select the paper tray.
3.
Select Drum Position, and then click Start.
1.
Load several sheets of fresh Letter or A4 plain paper
in paper tray 1, 2, 3, or 4.
2.
Select the paper tray.
3.
Select Media side edge, and then click Start.
Approximate
Complete description
time
2 to 22 minutes
„Carriage-to-carriage
alignment"
auf Seite 144
8 to 30 minutes
„Carriage Stopping
Accuracy calibration"
auf Seite 141
2 minutes
10 to 11 minutes
„Tetris sensor (SN58)
calibration"
auf Seite 163
1 second
„Pen Density
Compensation
calibration"
auf Seite 149
2 to 3 minutes
„Top-of-form Position
calibration"
auf Seite 163
3 to 4 minutes
„First Nozzle Position
calibration"
auf Seite 164
2 to 3 minutes
„Drum Position
calibration"
auf Seite 140
2 to 3 minutes
„Media Side Edge
calibration"
auf Seite 139
DEWW

Werbung

loading

Diese Anleitung auch für:

Cm8050 color mfp