Tray 1 calibrations
●
Tray 1 Paper-Width Guide calibration
Tray 1 Paper-Width Guide calibration
Purpose
The Tray 1 paper-width guide must be calibrated to correctly detect the width of media in Tray 1.
When to run
Run this calibration in the following situations:
●
Tray 1 is replaced.
●
Print margin problems on pages fed through Tray 1 exist and the media size in tray 1 is not reported
correctly.
Required time
2 minutes
Internal operation
The Tray 1 media guide is moved to match the width of the paper. The width measurements are
made from the inside edge of Tray1 closest to the front of the MFP, to the inside edge of the width
slider.
The Tray 1 paper-width guide moves a variable resistor. The resistor value is calibrates using
predefined positions. The calibration results are stored in NVM for use when printing from Tray 1.
Instructions
▲
See
„Engine Calibrations 2" auf Seite
DEWW
60.
Tray 1 calibrations 153