In order for the blocks for the safety program to be generated automatically, fail-
safe must be activated in the F-CPU. To activate fail-safe, select Fail-safe in
the General tab in the directory tree. The checkbox F-capability must be
activated in the mask under F-activation. If not, fail-safe must be activated by
selecting the button Enable F-activation.
As the F-CPU has activated Device replacement without exchangeable
medium is set by default in the options. For the example it has to be switched off.
To deactivate the setting, select the General tab in the directory tree and then
select the directory PROFINET interface[X1] -> Advanced options ->
Interface options. In the mask the Support device replacement
without exchangeable medium checkbox must be deselected.