Herunterladen Inhalt Inhalt Diese Seite drucken

TR-Electronic AD 582 Serie Gesamt-Bedienungsanleitung Seite 310

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.4.2 F-Runtime Group
To facilitate handling, the safety program consists of an F-Runtime Group. The F-
Runtime Group is a logic construct consisting of a number of related F-blocks, which is
formed internally by the F-System.
The F-Runtime Group comprises:
● an F-Organization Block FOB_RTG1 (OB123)
● an F-Function Block Main_Safety_RTG1 (FB1)
● an F-Data Block Main_Safety_RTG1_DB (DB1)
To set or change the "F-Runtime Group", go to Project tree and in the
directory tree select the entry CD_75_-EPN_PROFIsafe -> PLC_1 [CPU
1511F-1 PN] -> Safety Administration by double-clicking with the left
mouse button. This opens the Safety Administration Editor in the work
area.
In the directory tree of the Safety Administration Editor select the
directory F-Runtime Group -> F-Runtime Group 1 [RTG1] with the left
mouse button. You can adapt the settings for the runtime group here. The default
settings are used in the example project.
Printed in the Federal Republic of Germany
08/06/2021
TR-ECE-TI-DGB-0292 v02
 TR-Electronic GmbH 2016, All Rights Reserved
Page 113 of 159

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ad 75 serieAdv582Adv75

Inhaltsverzeichnis