4.4.2 F-Runtime Group
To facilitate handling, the safety program consists of an F-Runtime Group. The F-
Runtime Group is a logic construct consisting of a number of related F-blocks, which is
formed internally by the F-System.
The F-Runtime Group comprises:
● an F-Organization Block FOB_RTG1 (OB123)
● an F-Function Block Main_Safety_RTG1 (FB1)
● an F-Data Block Main_Safety_RTG1_DB (DB1)
To set or change the "F-Runtime Group", go to Project tree and in the
directory tree select the entry CD_75_-EPN_PROFIsafe -> PLC_1 [CPU
1511F-1 PN] -> Safety Administration by double-clicking with the left
mouse button. This opens the Safety Administration Editor in the work
area.
In the directory tree of the Safety Administration Editor select the
directory F-Runtime Group -> F-Runtime Group 1 [RTG1] with the left
mouse button. You can adapt the settings for the runtime group here. The default
settings are used in the example project.