Maintenance
8.1
Maintenance table
Interval
Maintenance work
Clean the station.
Weekly
Perform a visual inspection.
n
Check oval gear meter for sediments due to leaks.
Ä More information on: Flow meter - oval gear meter OGM
Carry out pump maintenance in the case of heavy loads
Monthly
(e.g. continuous operation).
Check that the connections on the suction and pressure lines are free from leaks
Quarterly
Ä More information on: Diaphragm metering pump TCD Turbo Pump
Check suction valves and pressure valves for dirt and tightness.
Ä More information on: Diaphragm metering pump TCD Turbo Pump
Check pump head screws for a secure fit.
Ä More information on: Diaphragm metering pump TCD Turbo Pump
Perform safety and functional testing of the entire system
Half-yearly
. (Leak-tightness of all components, replacing tubing and pipelines, where
needed)
If necessary, check the function of upstream system disconnectors.
Annually
n
Check oval gear meter for function.
n
Replace seals.
Ä More information on: Flow meter - oval gear meter OGM
MAN053089 Rev. 1-11.2023
PLUS
[ECOLAB]
PLUS
[ECOLAB]
62
Personnel
Operator
Operator
Mechanic
Mechanic
Mechanic
Mechanic
Service personnel
Service personnel
Service personnel