Assembly and connection
14
12
Fig. 15: Extending the valve block
9.
Unlock the retaining clamp
connection
10. Install the extension block with three solenoid valves on product valve P9 using a
coupling piece
11. Mount the grommet connection
12. Mount a closed threaded connection on the bottom of product valve P12.
13. Place the extended valve block on the support plate ( Fig. 14 ,
place with five mounting nuts.
14. Install the solenoid valve distributor block in reverse order.
15. Install additional strain relief screw fittings ( Fig. 13 ,
16. Connect product valves P10–P12 to the controller according to the circuit diagram.