Industrial RFID system - Read/write head
4
Product description (continued)
The security status for the EPC, TID and USER memory
banks can be set as follows:
EPC
Unlock
Lock
TID
USER
Read
Allowed
Allowed
(EPC, TID,
USER)
Write
Allowed
Password
(EPC,
USER)
Status
Yes
Yes
reversible
Details on the different memory banks and the
Lock and Kill functions can be found in the
UHF-RFID standards ISO/IEC 18000-63 and
EPCglobal
Class-1 Generation-2.
TM
4.4

Display elements

Balluff Standard (delivery state)
Signal
Green, static
The device is ready.
Green, alternating
IO-Link communication is active.
with LED off in a
ratio of 10:1, 1 s
period
Red, static
General error
Red, static
The sensor is currently in Teach-In
mode.
Red, flashing, 3 Hz
Short circuit at Pin 2 or Pin 4 (see
chapter 6.3 on page 21).
Yellow, static
CP signal (data carrier within RFID
range)
Yellow, flashing,
The device is operated outside of
3 Hz
specifications.
Orange, flashing,
Poor signal quality (number of
1 Hz
bad data carrier accesses)
Blue, static
Maintenance must be performed.
Blue, flashing, 3 Hz
The ping can be activated via a
system command to find the
device again.
Blue, flashing, 5 Hz
Reader active
Tab. 4-1:
Meaning of the Balluff Standard LED states
www.balluff.com
Unlock
Lock
perma-
perma-
nent
nent
Allowed
Allowed
Allowed
Locked
No
No
Meaning
Namur Standard
Signal
Green, static
The device is ready. Diagnosis
functions are on.
Static white
The device is ready. Diagnostic
functions are off.
Green, alternating
IO-Link communication is active.
with LED off in a
ratio of 10:1, 1 s
period
Red, static
General error
Red, static
The sensor is currently in Teach-In
mode.
Red, flashing, 3 Hz
Short circuit at Pin 2 or Pin 4 (see
chapter 6.3 on page 21).
Yellow, static
CP signal (data carrier within RFID
range)
Yellow, flashing,
The device is operated outside of
3 Hz
specifications.
Orange, flashing,
Poor signal quality (number of
1 Hz
bad data carrier accesses)
Blue, static
Maintenance must be performed.
Blue, flashing, 3 Hz
The ping can be activated via a
system command to find the
device again.
Blue, flashing, 5 Hz
Reader active
Tab. 4-2:
Meaning of the Namur Standard LED states
4.5

Labeling

1)
Order code
1)
Type
2)
3)
Serial number
Fig. 4-5:
Printing (extract, example)
Meaning
3)
2)
english
11