BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
10

Technical data

10.1

General features

One read/write head integrated
The read/write head is suitable for dynamic and static
operation.
Energy supply of the data carrier by the read/write
head by means of carrier signal
10.2

Ambient conditions

Ambient temperature
Storage temperature
Protection class according to
IEC 60529 (with single-ended
cordset in screwed condition)
Operation
2)
Altitude
3)
Relative humidity
Contamination
Vibration/shock
EMC
10.3

Electrical data

Operating voltage V
4)
S
Rated voltage
Residual ripple
Current consumption at 24 V,
without load
Standby
Active
Transmitting power max. (ERP/
EIRP)
Antenna polarization
Radio characteristics (radiated power, antenna
gain, etc.) are country-specific due to different
national regulations and depend on the device
variant.
For country-specific details on conformity and
approval, see the enclosed information or
www.balluff.com on the product page.
www.balluff.com
0...70 °C
−20...+85 °C
IP68 and IP69K
1)
Indoors
≤ 2000 m (above sea
level)
≤ 100 % (≤ 70 °C)
Degree of
contamination 2
EN 60068-2-6/27/32
Country-specific
18...30 V DC
24 V DC
5 %
≤ 50 mA
≤ 200 mA
18 dBmERP /
20 dBmEIRP
Circular
10.4

Electrical connection

IO-Link/Power connection
10.5

Output / Interface

Interface (Pin 4)
Digital output (Pin 2)
Output voltage V
 / V
Low
High
Output current (limited)
10.6

Mechanical data

Housing material
Dimensions (L × D)
Weight
1)
IP rating was not evaluated by UL
UL: The unit is for indoor use only.
2)
UL: The unit is intended to be used up to an altitude of 2000 m only.
3)
UL: This device is intended to be supplied by a UL Listed and CSA
4)
Certified Power Unit with "Class 2" or LPS power source.
M12 integral plug, 4-pin,
A-coded
IO-Link Revision 1.1
230400 kBit/s (COM 3)
0 V / V
– 0.3 V
S
≤ 100 mA
Stainless steel, PBT
98 × 30 mm
65 g