Herunterladen Inhalt Inhalt Diese Seite drucken

Examples - Balluff BIS U-4A7-082-01C-07-S4 Betriebsanleitung

Industrial rfid-system – schreib-/lesekopf
Vorschau ausblenden Andere Handbücher für BIS U-4A7-082-01C-07-S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
8.9

Examples

The commands are explained with the standard
profile (32 bytes of process data). If the CCM
profile is set, the 2nd bit string moves from
subaddress 0x1F to subaddress 0x0F (see
output/input buffer in chapter 8.5).
1.
Read 62 bytes at read/write head, start
address 10
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x01
0x02
Start address 0x0A
0x03
Start address 0x00
0x04
Number of bytes 0x3E
0x05
Number of bytes 0x00
0x00/0x1F
Set AV bit
3.
Process input buffer:
0x01...0x1E
Copy first 30 bytes
Process output buffer:
0x00/0x1F
Invert TI bit
5.
Process input buffer:
0x01...0x1E
Copy another 30 bytes
Process output buffer:
0x00/0x1F
Invert TI bit
7.
Process input buffer:
0x01...0x02
Copy last 2 bytes
Process output buffer:
0x00/0x1F
Reset AV bit
www.balluff.com
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit
0x01...0x1E
Enter first 30 bytes
0x00/0x1F
Invert TO bit
0x00/0x1F
Set AE bit
4.
Process input buffer:
0x00/0x1F
Set AA bit
0x01...0x1E
Enter another 30 bytes
0x00/0x1F
Invert TO bit
0x00/0x1F
Set AE bit
6.
Process input buffer:
0x00/0x1F
Set AA bit
0x01...0x02
Enter last 2 bytes
0x00/0x1F
Invert TO bit
0x00/0x1F
Set AE bit
8.
Process input buffer:
0x00/0x1F
Reset AA bit
0x00/0x1F
Reset AE bit
english
63

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis