BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
3.
Read 62 bytes at read/write head, start
address 10, problem while reading
If a problem occurs after data sending has
started, the AF bit is delivered instead of the AE
bit with the corresponding status number. The
AF status message is dominant. It is not
possible to specify which data is not correct.
Setting the AF bit cancels the assignment and
declares it as finished.
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x01
0x02
Start address 0x0A
0x03
Start address 0x00
0x04
Number of bytes 0x3E
0x05
Number of bytes 0x00
0x00/0x1F
Set AV bit
3.
Process input buffer:
0x01...0x1E
Copy first 30 bytes
Process output buffer:
0x00/0x1F
Invert TI bit
5.
Process input buffer:
0x01
Copy status number
Process output buffer:
0x00/0x1F
Reset AV bit
www.balluff.com
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit
0x01...0x1E
Enter first 30 bytes
0x00/0x1F
Invert TO bit
0x00/0x1F
Set AE bit
4.
Process input buffer:
When problem has occurred!
0x01
Enter status number
0x00/0x1F
Set AF bit
6.
Process input buffer:
0x00/0x1F
Reset AA and AF bits