BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
Radio profile
Parameter-ID:
0x0084 – Subindex 1
UHF-Manager:
Menu: Device settings > Advanced
parameters... > RF settings
The radio profile defines which connection parameters are
used on the air interface between the data carrier and the
processor unit:
Tx: Bit rate forwards, i.e. from read/write head to data
carrier
Rx: Link frequency backwards, i.e. from data carrier to
read/write head
Coding: Coding backwards, i.e. the coding with which
the data carrier responds
The following radio profiles can be set:
Profile
Parameter
value
1
0x00000000
2
0x00000002
3
0x00000600
4 (Factory setting)
0x00000602
5
0x00030600
6
0x00030602
7
0x00000902
8
0x00030902
9
0x00030C01
10
0x00030C02
11
0x00030C03
12
0x00060F02
Due to the different international radio
regulations, the available radio profiles depend
on the country variant used. For country-
specific details on conformity and approval, see
the enclosed information or www.balluff.com
on the product page.
www.balluff.com
TX bit rate
RX link
[kBit/s]
frequency [kHz]
40
40
40
40
40
160
40
160
80
160
80
160
40
250
80
250
80
320
80
320
80
320
160
640
RX coding [FM0
RX bit rate [kBit/s]
\ Miller-n]
FM0
40
M4
10
FM0
160
M4
40
FM0
160
M4
40
M4
62.5
M4
62.5
M2
160
M4
80
M8
40
M4
160