System integration (continued)
4.
Writing 62 bytes to read/write head, start
address 20
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x02
0x02
Start address 0x14
0x03
Start address 0x00
0x04
Number of bytes 0x3E
0x05
Number of bytes 0x00
0x00/0x1F
Set AV bit
3.
Process output buffer:
0x01...0x1E
Enter first 30 bytes
0x00/0x1F
Invert TI bit
5.
Process output buffer:
0x01...0x1E
Enter another 30 bytes
0x00/0x1F
Invert TI bit
7.
Process output buffer:
0x01...0x02
Enter last 2 bytes
0x00/0x1F
Invert TI bit
9.
Process output buffer:
0x00/0x1F
Reset AV bit
66
english
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit
0x00/0x1F
Invert TO bit
4.
Process output buffer:
0x01...0x1E
Copy first 30 bytes
Process input buffer:
0x00/0x1F
Invert TO bit
6.
Process output buffer:
0x01...0x1E
Copy another 30 bytes
Process input buffer:
0x00/0x1F
Invert TO bit
8.
Process output buffer:
0x01...0x02
Copy last 2 bytes
Process input buffer:
0x00/0x1F
Set AE bit
10. Process input buffer:
0x00/0x1F
Reset AA and AE bits