BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
9.
Unselect
Cancel a data carrier selection made with the Select
command.
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x41
0x00/0x1F
Set AV bit
3.
Process output buffer:
0x00/0x1F
Reset AV bit
70
english
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit
0x00/0x1F
Set AE bit
4.
Process input buffer:
0x00/0x1F
Reset AA and AE bits