Industrial RFID system - Read/write head
8
System integration (continued)
8.3.2

Temporary data

The following data are not stored on the EEPROM and are
therefore reset to the default values after a restart/reset.
ISDU – Temporary parameter data
Name
Temporary RFID parameters
Transmitting power on read
Access password
Auto setup state
Memory bank
Transmitting power on read (current)
Parameter-ID:
0x0085 – Subindex 1
UHF-Manager:
Menu: Device settings > Parameters...
> Transmitting power
After switching on or after a restart of the read/write head,
the current transmitting power is taken from the parameter
Transmitting power on read (default). Depending on the
requirements, the transmitting power can be temporarily
changed via the parameter Transmitting power on read
(current). The setting is retained until it is changed again or
the read/write head is restarted.
The set transmitting power is used for read operation.
The desired power in quarter dBm is applied as the
parameter value.
Parameter value = P(dBm) × 4
Adjustable power:
−9...+16 dBmERP
(corresponds to 0.125...40 mW)
1)
−7...+18 dBmEIRP
(corresponds to 0.2...64 mW)
1)
1)
The highest possible antenna power depends on the device variant.
Length
Permissible
[bits]
values
16
−80...+160
Depending on the device variant, the
specifications for the transmitting power are to
be understood as ERP values (Equivalent
Radiated Power) or EIRP values (Equivalent
Isotropically Radiated Power). The respective
valid information can be found in the information
sheet on conformity and approvals.
36
english
Index
Subindex
0x0085 (133)
0
1
2
3
4
Factory
Meaning
setting
40
Current
10 dBm
transmitting power
(10 mW)
in ¼ dBm (ERP or
EIRP)
Access
Length
Data type
R/W
8 bytes
Record
R/W
2 bytes
INT16
R/W
4 bytes
UINT32
R/W
1 byte
UINT8
R/W
1 byte
UINT8
Access password
Parameter-ID:
0x0085 – Subindex 2
UHF-Manager:
Action area > Read and write tab
If a password-protected data carrier is to be accessed, the
data carrier can be unlocked for further interaction using
the Access password parameter. The password must be
transferred in LSB first format.
If no data carriers with different passwords are in use, it is
sufficient to send the parameter once to the read/write
head. The password remains stored in the read/write head
until the read/write head is restarted.
Adjustable values:
4-byte password (hexadecimal, default: 00 00 00 00)
Length
Permissible
[bits]
values
32
00000000...
FFFFFFFF
Data
Default
Storage
No
No
40
No
0x0000
No
0
No
3
Factory
Meaning
setting
00000000
Access password