8.7.14 Command identifier 0x56: Read RSSI (Receive
Signal Strength Indicator)
Returns the RSSI of a data carrier previously selected with
the Select command. The RSSI is a value proportional to
the signal strength of the received response signal of the
data carrier.
Command:
Subaddress Meaning
0x00
1st bit string
0x01
Command
recognition
0x02
RSSI Type
...
None
0x1F
2nd bit
string
The RSSI value is returned in the form of an I and a Q
component as a power level measured in dBm. In most
cases it is sufficient to consider the component with the
higher value.
Subaddress Meaning
0x00
1st bit string
0x01
I-value
0x02
Q-value
...
None
0x1F
2nd bit
string
or
Input buffer: Status message
Subaddress Meaning
0x00
1st bit string
0x01
Status code
...
None
0x1F
2nd bit string If the 1st and 2nd bit
www.balluff.com
Functional description
0x56: Get RSSI
0: Real-Time RSSI
1: Pilot tone RSSI
2: Data RSSI
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
Functional description
−40...−90
−40...−90
No meaning
If the 1st and 2nd bit
strings match, valid data is
present.
Functional description
Provides information about
the status of a request.
No meaning
strings match, valid data is
present.
english