BIS U-4A7-082- _1C-07-S4
Industrial RFID system - Read/write head
8
System integration (continued)
8.
Selecting a data carrier for further processing
(for configuration with 32 byte buffer size)
For configuration with EPC size of 12 bytes
Controller
1.
Process output buffer
(note sequence):
0x01
Command recognition 0x40
0x02
Type EPC 0x00
0x03
Length of EPC 0x0C
0x00/0x1F
Set AV bit
3.
Process output buffer:
0x01...0x0C
Enter 12 byte EPC
0x00/0x1F
Invert TI bit
5.
Process output buffer:
0x00/0x1F
Reset AV bit
www.balluff.com
Identification system
2.
Process input buffer
(note sequence):
0x00/0x1F
Set AA bit, invert TO bit
4a.
Process output buffer:
0x01...0x0C
Save EPC
4b.
Process input buffer:
0x00/0x1F
Set AE bit
6.
Process input buffer:
0x00/0x1F
Reset AA and AE bits