Error codes

Status
Functional description
code
0x00
Everything OK.
0x01
Assignment cannot be executed because
there is no data carrier in the range of the
read/write head.
0x02
Reading of data carrier not possible.
0x03
Data carrier was removed from the area of
the read/write head during reading.
0x04
Cannot write to the data carrier.
0x05
Data carrier was removed from the range of
the read/write head during writing.
0x07
No or invalid command identifier with AV bit
set or the number of bytes is 0x00.
0x0D
Communication with the read/write head is
interrupted.
0x0E
CRC of the read data and CRC of the data
carrier do not match.
0x0F
1st and 2nd bit string are unequal. The 2nd
bit string must be served.
0x20
Addressing of the read/write assignment is
outside the memory area of the data carrier.
0x21
This function is not possible with this data
carrier.
0x30
License key incorrect.
0x31
Invalid parameters set.
0x32
Password required.
0x33
Password invalid.
0x34
Memory range locked.
0x35
Value range of parameter incorrect.
0x36
More than one data carrier in the field of the
antenna (does not apply to the single tag
command)
0x44
Undefined device behavior
0x45
KA bit active, command cannot be executed.